ECOGRAIN
Equipment catalogLouver grain dryer
FLATUM
FLATUM · Louver grain dryer
FLATUM · Louver grain dryer
Louver grain dryer

FLATUM

A modular louver grain dryer designed for efficient and safe drying of pre-cleaned grain and seeds with uniform heating and reduced energy consumption.

Back to equipment

Technical specifications

The FLATUM model range is taken from the supplied technical table. Capacity is shown in t/h.

SeriesRange, t/hModels and capacity, t/h
Series 815–40FLATUM 3-8 16FLATUM 4-8 17FLATUM 5-8 25FLATUM 6-8 26FLATUM 7-8 27FLATUM 8-8 34
Series 1020–60FLATUM 3-10 23FLATUM 4-10 31FLATUM 7-10 48FLATUM 8-10 56
Series 1230–60FLATUM 5-12 34FLATUM 6-12 35FLATUM 7-12 51FLATUM 8-12 52
Series 1445–70FLATUM 5-14 49FLATUM 6-14 57FLATUM 7-14 66
Series 1645–70FLATUM 5-16 50FLATUM 6-16 52FLATUM 7-16 68FLATUM 8-16 69
Series 1860–100FLATUM 5-18 63FLATUM 6-18 73FLATUM 7-18 88FLATUM 8-18 98
Series 2470–110FLATUM 6-24 77FLATUM 7-24 80FLATUM 8-24 103FLATUM 9-24 106
Series 28135–220FLATUM 6-28 117FLATUM 7-28 131FLATUM 8-28 157FLATUM 9-28 176

Dimensions, weight and capacity

SeriesModulesColumnsBurnersLinearHeight, mmWidth, mmLength, mmMass, kgStructural mass, tCapacity, m³
83–881 / 11 (2)11860–22210523010450–1231013720–2969011,419,6–52,3
103–8101 / 1 (2 / 2)1 (2)11860–22210586511380–1325017380–3757014,824,5–65,4
125–8122 / 21 (2)16290–2250065001325028640–4211016,749,0–78,47
145–8142 / 2 (3 / 3)1 (2)16290–2250071351325034260–5185020,857,2–91,5
165–8162 / 2 (3 / 3)1 (2)16290–2250078001325038760–5498022,465,4–104,6
185–8182 / 2 (4 / 4)1 (2)16290–2250084051325046430–6582026,873,5–117,6
246–9243 / 3 (4 / 4) (5 / 5)1 (2)19730–25940101301325065740–9242033,5117,6–176,5
286–9285 / 5 (6 / 6)219730–25940109451325085240–12006038,8137,3–205,9

Description

The modular grain dryer is designed for efficient and safe drying of pre-cleaned grain and seeds to the required moisture level. It is installed in post-harvest grain and seed processing lines as well as dedicated seed and food-grain preparation plants.

Modular louver dryers are a further development of the classic shaft dryer and an advanced solution for cross-flow heat transfer. A guide column directs the grain flow and provides high drying quality with significantly lower energy consumption.

The grain mass moves in a zigzag path under gravity, parallel to the bends of the louver walls. This intensive movement provides full and uniform contact with the circulating heated air.

Hot air enters the inlet channel from the closed rear side. Passing through the grain layer, it heats the grain and removes moisture before moving into the outlet channel.

As grain flows down special louver flaps on both sides of the channel, it remains a dense continuous column while being intensively mixed. This mixing is the key difference from conventional shaft dryers with cross-flow heating.

Continuous mixing provides uniform heating and faster moisture removal. The high mixing coefficient makes it possible to achieve uniform final moisture and, when required, use a higher drying temperature without overheating the grain.

The design is also environmentally efficient. Larger air-duct cross-sections reduce air velocity and therefore reduce dust emissions.

Advantages

LOW FIRE HAZARD

LOW FIRE HAZARD

Sensors are integrated into an alarm and automatic burner shutdown system. A fire-extinguishing system is available as an option.

MODULAR DESIGN

MODULAR DESIGN

Depending on the selected dryer, capacity increases by 10–20% with each added module. Standardized parts and assemblies simplify repair and maintenance.

LOW OPERATING COSTS

LOW OPERATING COSTS

Electrical power demand is 15–20% lower. Shaft insulation minimizes heated-air losses. Electricity savings can reach 30%.

RELIABLE DRYER OPERATION

RELIABLE DRYER OPERATION

No stagnant zones, separated grain flows and no counter-flowing grain inside the shaft. Self-cleaning is provided and the probability of grain bridging during drying is minimal.

FUEL FLEXIBILITY

FUEL FLEXIBILITY

The large cross-section and volume of the hot-air chamber allow different fuel types and simplify burner replacement.

LOW ENERGY CONSUMPTION

LOW ENERGY CONSUMPTION

20–23 kW at 25 t/h. Competitive cost combined with high throughput and lower specific energy consumption.

Design

FLATUM process flow diagram

FLATUM comprises a dryer body with a loading hopper, drying-column modules, fans, burner equipment, a cleaning system, thermal insulation, service platforms and automated control.

Air recirculation improves drying uniformity and optimizes heating and energy consumption. The loading-hopper distributor provides even grain flow around the dryer perimeter.

Scope of supply

01Dryer body with loading hopper.
02Drying shafts (modules).
03Fans.
04Discharge table with integrated conveyor (from Series 10).
05Cleaning system with serviceable dust-collection components.
06Thermal insulation of the inlet box and shafts.
07Service platforms and ladders for each level.
08Insulation of the burner equipment zone.
09Control panel with cabling, level and temperature sensors, and frequency converters.
10Air recirculation system for improved drying uniformity, optimized heating and energy consumption.
11Loading-hopper distributor for uniform grain flow around the dryer perimeter.

Request a quote

FLATUM · Louver grain dryer

Fill in the form and we will contact you

By clicking the button, you consent to the processing of personal data

Application sent!

Our manager will contact you shortly.

An error occurred. Try again later or call us.

Fill in the form and we will contact you

By clicking the button, you consent to the processing of personal data

Application sent!

Our manager will contact you shortly.

An error occurred while sending. Please try again later or call us.